Samson B Series B900 Specifications

Browse online or download Specifications for Audio amplifiers Samson B Series B900. Samson B Series B900 Specifications User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
®
www.versa-valves.com
Versa Products Company, Inc., 22 Spring Valley Road, Paramus, New Jersey 07601 ● TEL: 201/843-2400 Fax: 201/843-2931
Versa BV., Prins Willem Alexanderlaan 1429, 7312 GB Apeldoorn, The Netherlands ● TEL: +01131-55-3681900 FAX: +01131-55-3681909
Control Valves and Components for
Process, Wellhead and Safety Shutdown Systems
BULLETIN
B316 2012
ISO 9001
CERTIFIED
Page view 0
1 2 3 4 5 6 ... 23 24

Summary of Contents

Page 1 - B316 2012

®www.versa-valves.come-mail: [email protected] Products Company, Inc., 22 Spring Valley Road, Paramus, New Jersey 07601 ● TEL: 201/843-2400

Page 2 - ACCESSIBILITY

10Single Solenoid Valves EXPilotControlled (inlet) Pressurepsi bar psi bar psi bar psi bar psi bar psi bar psi bar psi bar psi bar p

Page 3 - CONTENTS GUIDE

11Solenoid-pilot operatedSolenoid-Pilot return(detented)Controlled (Inlet) PressureEXPilot INPilotpsi bar psi bar0-200 0-14 15-175 1-12Auxiliary pilot

Page 4

12PRESSURESControlled (inlet) pressure & auxiliary pilot pressure (when required) are the same as those shown for the corresponding solenoid valve

Page 5 - Manually Operates Valves

13PRESSURESControlled (inlet) pressure & auxiliary pilot pressure (when required) are the same as those shown for the corresponding solenoid valve

Page 6 - Pilot Operated Valves

14PRESSURESControlled (inlet) pressure & auxiliary pilot pressure (when required) are the same as those shown for the corresponding solenoid valve

Page 7 - Mechanically Operated Valves

15OPERATING PRESSUREAND WEIGHTWeightSYSTEM PRESSUREALLOWABLE BACKPRESSUREat Outlet Port (Two-Way)or Exhaust Port (Three-Way)Two-Way (2/2)Block & B

Page 8

16MAIN SUPPLY RESET VALVES SELECTORKnob Actuator Pilot ActuatorValve SufxNon-latching Manual Pin Latch Non-indicating Indicating Air Pilot Air Latch

Page 9

17INEXCYLINDICATOR DEVICE REFFERENCE • RED INDICATES THAT THERE IS NO PRESSURE IN THE PILOT CHAMBER • GREEN INDICATES THAT THE PILOT CHAMBER I

Page 10 - SERIES B316 VALVES

18INEXCYLREDGREENINEXCYLREDGREENINEXCYLINEXCYL⅛” NPT INLINEPILOT LATCHPORTMANUALLATCHPIN⅛” NPT INLINEPILOT LATCHPORT ● GREEN INDICATES THAT THE PILOT

Page 11 - Controlled (Inlet) Pressure

19REDGREENINEXCYLMANUAL OVERRIDE BUTTONOPTIONAL (SUFFIX -ME).4711.82.0953.224” (610mm) LEADS⅛” NPT PILOT PORT(EX-PILOT VALVES ONLY)MANUAL LATCH PIN3.4

Page 12

2THE COMMITMENT CONTINUES Fluid Power is our business. It is our only business, so we have to be good at it. Since its beginning in 1949, Versa has

Page 13 - (d) FLAMEPROOF

20BAA-3308-900R BAA-3308-550RConstruction:Body. Internals, Caps316 stainless steel (NACE MR-01-75)Hardcoated Aluminum (MIL-A-8625E, Type III, Class1)S

Page 14

21BAA-3308-900RA BAA-3308-550RA316 Stainless Steel (NACE MR-01-75)Construction: Body, Internals, CapsHardcoated Aluminum (MIL-A-8625E, Type III, Clas

Page 15 - Porting Size and Flow

22BAA-3308-550RABConstruction: Body, Internals, CapsHardcoated Aluminum (MIL-A-8625E, Type III, Class 1) Seals FKM (uorocarbon) Fasteners & By

Page 16 - STAINLESS STEEL CONSTRUCTION

23ValveProduct NumberRepairKit NumberALL*B-3308-316Manual- BSI or BIACam- BSCPilot- BSP or BPP *Additional nonhazardous solenoid parts not included in

Page 17 - Knob: Latching, Indicating

The warnings below must be read and reviewed before designing a system utilizing, installing, servicing, or removing a Versa product. Improper use, in

Page 18 - INDICATOR DEVICE REFERENCE

3Versa exercises diligence to assure that information contained in this catalog is correct, but does not accept re-sponsibility for any errors or omis

Page 19 - Type: Specialized Application

4TYPE OF SERVICETemperature Range (Medium/Ambient Temperature)Intermittent Duty Service Continuous Duty ServiceAC or DC AC DCCoil Solenoid Plunger* Co

Page 20 - Transmitting Relay Circuit

5Ø1.81461.025.4Ø MIN PANEL HOLE4.64117.9.15 3.8TRAVEL6.42163Ø1.025.4MIN PANEL HOLEMAX PANEL THICKNESS.5012.2.317.9WITH SUFFIX OPTION -43Ø1.81460.164.

Page 21 - Receiving Relay Circuit

6Pilot OperatedSpring ReturnControlled (inlet) Pressurepsi bar psi bar psi bar psi bar psi bar psi bar psi bar psi bar psi bar psi

Page 22 - Consult factory for actual

7min stroke0.133.5max stroke0.154.11.2531.7sq.0.184.6¼” NPT3 PORTS1.6642.13.3184.0.348.6.5012.71.025.41.025.4.133.3Ø.276.9AIN EXAIN EX3/2-(Three-Way)

Page 23 - Series B316 B550 B900 VALVES

8Sufx IdenticationProtection ClassicationArea Classication and (Gas Grouping)Certication- (Conformance)Ingress ProtectionNone or-UGeneral Purpose

Page 24 - DESIGN APPLICATION WARNINGS

9PRODUCT NUMBER COIL CODES: Complete product numbers require, when applicable, a coil code that represents the desired coil current type, frequency an

Comments to this Manuals

No comments